Wall Opening Design Tool

OpenWall

OpenWall sizes the beam, columns and footing for a wall opening in minutes — then gets you a permit-ready drawing sealed by a licensed professional engineer. Professional engineers and BCIN holders can also use this tool to get a drawing ready to review and stamp in seconds.

Opening & location

Basic geometry of the wall opening being created.

Plan-view sketch of opening length, S1 and S2 Top-down sketch showing the wall opening between two posts, with joist spans S1 above and S2 below landing on the beam. Post A Post B beam Opening length S1 S2 joists landing on bearing element, side 1 joists landing on bearing element, side 2
S1 / S2 = framing spans landing on a load-bearing element (existing beam, wall, etc.), each side
Limited to 2 floors above grade for now

Important safety & design notes

Please read these before any work begins. They apply to every design this tool produces.

What this design assumes

  • The opening is inside the building, in a wall carrying floor loads only — not a roof, snow, deck or garage load.
  • Loading is ordinary residential: 0.5 kPa dead load and 1.9 kPa live load. Tile, stone, masonry, water features and unusually heavy finishes are not covered.
  • The wall carries gravity load only. It is assumed not to be a shear wall and not to provide lateral, wind or earthquake resistance.
  • Lumber is SPF No. 2 grade or better; steel is CSA G40.21 350W.
  • The structure below the opening — existing beams, columns, walls and footings — has enough capacity for the added load. This tool does not check it.
  • Soil under any new footing can carry the bearing pressure entered. No soil testing has been done.

Before and during construction

  • Temporary shoring is required. The existing structure must be properly supported before any part of the wall is removed. This is the contractor's responsibility.
  • Verify every dimension on site. Do not scale drawings.
  • Provide minimum 89 mm (3½") bearing at each end of the new beam.
  • Where a new column passes through a floor without landing on an existing beam, carry it continuously down to the basement slab or a new footing. Keep wood clear of moisture.
  • New footings must bear on undisturbed soil. Stop work and get advice if you find fill, soft ground or water.
  • A building permit is normally required. Check with your municipality before starting.

Stop and get professional advice if

  • Anything on site differs from what you entered here.
  • The wall supports a roof, a stair, a bearing point from above, or an engineered floor system.
  • You find cracking, sagging, rot, insect damage or previous alterations.
  • The building is older and may contain asbestos or lead — these must be assessed before demolition.
This tool gives preliminary sizes only. It is not a stamped design and must not be used for construction or submitted for a permit on its own. A licensed professional engineer must review the actual conditions and seal the drawings first.

Output summary

Snapshot for the job sheet.

OpenWall Pro — for professionals

If you're a licensed P.Eng or a BCIN-qualified designer, get a drawing ready to review and seal in seconds — in your own title block, with your firm name and logo — and save yourself hours of drafting time. Not for homeowners or contractors: if that's you, use the sealed drawing option above instead.

Need a change to something you already ordered?

Use your order reference — it was in your confirmation email.

Drawing preview — unsealed
fit
Two sheets \u2014 S01 and S02. Use + to zoom in and read the notes.